Repair of the Breville BOV450XL Mini Smart Oven

We have been enjoying using the Breville Mini Oven for about two years.  It has not only replaced the toaster on the kitchen counter, but it has mostly eliminated the use of the large electric oven.  The oven retails for about $150.  A few weeks ago the oven suddenly went dead without a beep or anything on the digital display.  We had usually unplugged the device when not using it to save the vampire power drain and avoid damage from the frequent 10 second power outages in our neighborhood.  The handy plug with the hole in it made this an easy task.

BrevilleBack

The first thought was, oh maybe it’s just a fuse.  But there is no user replaceable fuse.  Searching the web did not turn up any information on how to fix the oven either.  What I did find was replacement parts at a site called eReplacement Parts.  They had a fuse assembly for the oven for just $4.57. With shipping it was almost $12 dollars.  It was not in stock and they gave no estimate as to when they might ship me one.  But it only took a couple of weeks before the UPS guy left one on the front porch.  They also gave email updates on the order.

Then the fun begins with the disassembly of the oven.  First remove all the exterior screws that hold the single piece of stainless that makes up the top and sides of the oven.  This will just loosen it and allow you to bend out the sides for access.  There are at least two screws that keep this wrapping attached to the chassis up near the front where the controls are.  I figured if I took those two out I would never get them back in since there is so little room to work with.  Remove the rear cover completely with the external screws.  Luckily the fuse assembly is attached to the back left of the oven.  Right below it is the temperature sensor.  The fuse is temperature sensitive, that is why it is attached to the inner frame that gets hot.

The eReplacement page has a picture of the fuse assembly.  You have just two screws that hold it to the frame and two wire connections.  The first one is directly connected to the black power cord with a crimp connector.  Connect the new fuse wire with a wire nut.  The other end has a slip off terminal connector that attaches to a connector at the bottom front of the control assembly.  The old one comes off easily with a tug using a pair of needle nose pliers.  Getting the new one on that connector is the hardest part of the job.  There is a connector on each side of your target connector, and the connectors are recessed.

BrevilleFront

Using Webstorm with Udemy AngularJS course by Dan Wahlin

I recently took the course AngularJS Jumpstart with Dan Wahlin on Udemy.  Dan does a great job and I highly recommend it.  In the course Dan uses the Brackets editor which has the advantage of being able to set your project as the root of the server.  This results in addresses such as:

“localhost:8080/index.html”

I use Webstorm for Angular and JavaScript development.  I could not find any way to get it to do this and ended up addresses like:

“localhost:63342/Angular/index.html”

The problem comes in when you use the node.js server for the course application.  Changing the server port to use 63342 causes a cross domain load error.  To get the application to work with Webstorm first modify the server.js node/Express file:

var allowedOrigin = 'http://localhost:63342';

app.get('/customers', function(req, res) {
    // Add the following line to fix cross domain errors
    res.header('Access-Control-Allow-Origin', allowedOrigin);
    res.json(customers);
});

Then for each app.get in the file add the res.header line.  There are other ways to do this such as using a router or a specialized middleware routine but this is the most straightforward way.

Next modify the customerFactory.js file to retrieve data from the 8080 port instead of defaulting to the application 63342 port:

(function() {
    var customersFactory = function($http) {

        var urlBase = 'http://localhost:8080';
        var factory = {};
        
        factory.getCustomers = function() {
            return $http.get(urlBase + '/customers');
        };
        
        factory.getCustomer = function(customerId) {
            return $http.get(urlBase + '/customers/' + customerId);
        };
        
        factory.getOrders = function() {
            return $http.get(urlBase + '/orders');
        }
        
        factory.deleteCustomer = function(customerId) {
            return $http.delete(urlBase + '/customers/' + customerId);
        }
        
        return factory;
    };
    
    customersFactory.$inject = ['$http'];
        
    angular.module('customersApp').factory('customersFactory', 
                                           customersFactory);
                                           
}());

A Website Health Check Page

Over the last two years I have supported a multifunction web site with many application settings, three databases, and several external web services.  The need to support this site on many different servers led to the development of a detailed diagnostic health check page for the application.  Some of the servers are controlled by the customer which makes debugging problems more difficult since you have to coordinate changes with remotely located support persons in different time zones.

The health check we have developed is written in ASP.Net web forms but could be easily converted to an MVC format.  The main purpose here is not focus on the presentation layer but to identify useful information to report and present some of the code used to gather information. 

The page supports three options:

  1. Simple Health Check – A fast check that does a quick database connection check and returns a code of 200 if successful else a 500.  This is performed if there is no valid query string values. 
  2. Get Version – Returns a simple one line version of the application version.  This is called by using a query string containing a “GetVersion” key with any value.
  3. Detailed Health Check – Does a detailed database check, web services check, and displays some non-sensitive application settings.  Called by a query string containing “details” key with any value.

The Database Section

image

The header of the page is set to the site name constant, “Mighty Site” in this example.  The current URL follows the site name.  This is helpful if you have one or more instances open for different locations.

In this example we check three databases.  The first check “Database Connections” is the same check called in the simple health check.  The function CheckDbConnection is called for each database and attempts to open a new connection.  Before trying, the connection timeout is set to 5 seconds.  This keeps you from having to wait the standard 30 seconds if the connection string is bad or the database is down.

Next a random stored procedure is executed for each database.  This tells you the database login you are using has execute permissions on stored procedures.

Our second database (DB2) needs full text search installed, which is not the default case when you install SQL Server.  The GetServerProperty function in the Helper class is called to retrieve the server property “IsFullTextInstalled”.

The next two lines the the date and time of the SQL Server instance and the IIS server.  In the example above, both are on the same localhost machine and are the same.  But we did have one occasion when the database was on a separate machine and just a few seconds difference caused one pop up routine to go into an infinite loop.

Web Services

image

The Mighty Site relies on a Single Sign On service to log users in, and a Data Service to get and update information about the users.  The ServiceHealthCheck function uses the Web API Client to make calls to the health check on these services and looks for a 200 OK return code.  If a service cannot be reached or returns a non-200 code, the row background will be pink and a DNS lookup is attempted on the URL.

image

Application Settings

The application has many settings in the appSettings.config file and it is useful to see some non-sensitive ones on the health check page.  You could also display database resident settings here.

image

Version Information

The website maintains version information in the App_GlobalResources\About.resx file. 

image

Time Zone Information

Unfortunately the Mighty Site was written years ago by some folks who didn’t believe in using UTC date times.  The system is based on the time zone where the server is located which causes a lot of headaches.

image

Conclusion

The ASPX file contains only a single line, the usual first line containing the Page, CodeFile, and other directives.  All of the page content is generated in the code behind with the help of the functions in the HTML Tables region.  The source code is available here.

Using Office365 Mail on Surface

Despite all the advances in the world it is still hard to turn around an aircraft carrier.  One of the first things I tried with my Surface was to connect to my company’s email on Office 365.  Under the Outlook tab it lists Exchange, Office 365, and Outlook.com.  However when you swipe on it, then choose Show More Details, you are presented with entry boxes for: Email address, Server address, Domain, Username, and Password.  Server?  Is that IMAP server?  Checking the 365 site, they had no information about Surface whatsoever.  It’s hard to get the info out to all corners of the empire.  I’ll just assume they want the IMAP server.  Domain?  I don’t think there is one associated with the 365 account.  I tried just leaving it blank and was able to connect.

VMware Standalone Converter Write Error

I have run the VMware Standalone Converter now from several different machines.  Each time I get an error that the file C:\ProgramData\VMware\VMware vCenter Converter Standalone\ssl\rui.crt cannot be opened.  The file is always there but cannot be accessed.  The file properties always show Administrators have full access, and my current user is an administrator.  Never the less, just set your logged in user to have full access to the folder and all will work fine.

Jungle Disk Service Hangs Up

I’ve been using Jungle Disk for nearly three years now for reliable, easy, and inexpensive cloud storage. The software uses Amazon S3 storage or their own Rackspace storage. Since I currently run five machines at home and one at work the network drive that Jungle Disk mounts is great for storing large files. It can also be configured to do automatic backups. For things that change everyday, I also run Windows Live Mesh.

Recently on my new Vista machine the Jungle Disk service would just hang in the starting state. I tried reinstalling several times with the same result. I resorted to the Jungle Disk help desk.

The first response was disappointing: make Jungle Disk an exception in the firewall and make sure ports 80 and 443 are open. Since none of the other machines running McAfee had this set, I didn’t think it would help. But of course I tried it to no avail.

I specifically asked how to remove all program information before the installation. Every time I tried reinstalling the software I was never asked for my Amazon S3 information. I had assumed it was a registry entry, but in fact for Vista it is stored in an XML file in C:\ProgramData\JungleDisk. Removing the files in that location fixed the problem and I was able to re-enter the Amazon information and run the program without the service hanging.

Only four or five hours of work for what I guess was a gamma ray striking some part of my disk drive since there had been no configuration changes or installs to prompt this behavior.

Winform Design Mode Rendering Error

We recently upgraded our main application to the latest version of the Infragistics controls. Everything converted, compiled, and ran fine. However, when you tried to open some forms in the Visual Studio designer, you got the message “The path is not of a legal form”. Looking at the project for these forms, they had invalid references to custom controls that used Infragistics controls. I deleted the references and added the newly compiled versions to eliminate the designer rendering error.

Since we do not remove the previous version of Infragistics the older controls are found at run time.

Visual Studio 2005: Key not valid for use in specified state

We have recently migrated all of our workstations to a different Windows domain at our office. Some folks were getting the following error when trying to open a DataSet in Visual Studio 2005:

Key not valid for use in specified state

The problem is caused because of the change of your username from the old domain to the new domain. This causes Visual Studio to not be able to properly decrypt some its settings.

The fix is to rename/delete the following file:

C:\Documents and Settings\YOUR USERNAME\Application Data\Microsoft\VisualStudio\8.0\ServerExplorer\DefaultView.SEView

You will now have to add back all your databases to the Server Explorer toolbox (but you only have to add them at a later time as you need them).

Thanks to Robert Stam for this tip.